Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com GU-154-F
page 44 of 132
ToolVox® X3
Administrator Guide
DTMF Dialing Volume – SetsthevolumeoftheDTMFtonesduringthedialingsequence
Recording Playback level – Setsthevolumeleveloftherecordingsplayedbackoutoftheunitand
totheguard.
Answer Ring count – NumberofRingsbeforetheunitwillanswer
Ring-In Unit Speaker – Enabletohearincomingcallringoutoftheunitspeaker
Enable Mass Notication System – EnablingwillforcetheIA4100toanswerincomingcallsand
passtheaudiototheamp/speakerarray.
Mass Notication Outputs - Ifdesiredselect1oftheAuxiliaryOutputsandarecordingtoplay
fromoneoftherecordingmemoryslotsabove.
Disable Battery Check - Yes-Donotcheckthebattery.No-Checkbatteryandcallnumberset
abovein“LowBattery”Section.
Hang up Methods
Wink Timing – 0=disabled,1-9=100msto900ms.Lengthofthewinksignalcomingfromthe
connectedphoneline.
Revert to dial tone – 00=disabled,01-991to99seconds.Continuoussoundforthisperiodoftime
willcausetheunittohangup.
Silent Time Out – 0to3,0=disabled,1=30sec,2=60sec,3=90sec.Silenceforthisperiodoftime
willcausetheunittohangup.
Reorder/Repeating Tones – 00=disabled,01to99=1to99cycles.Thisisthenumberofrepeating
cyclesthatwillcausetheunittohangup.
Call Time Out – 00=disabled,01-99=1to99minutes.DTMFtonesBBBBBwillplaytoboth
partiesduringacallnotifyingthem30secondspriortocalldisconnect.Atthistimethecallcanbe
extendedbyenteringtheINcallcommand31.Oncethetimerhasexpired,ifcommand31isnot
entered,theunitwillhangup.
Wink Voltage Minimum – MinimumvoltagechangetointerpretasaWINK.0=5Vthru9=14V.
Minimum Ring Voltage Detection – Threshold-0=13Vrms,1=19Vrms,2=40Vrms.
Maximum Ring Frequency – 0=75Hz,1=50Hz,2=35Hz.