Administrator Guide
CBEventServerPlugin Toolvox with IP Address=(192.168.10.5) is inactive.
CBEventServerPlugin Toolvox with IP Address=(192.168.10.5) came back on-
line.
Symptoms and resolutions
Alarms are not being generated when calls are made
Datafromthedevice(s)isnotmakingittotheSmartClient.Therearemanypossiblecausesfora
lapseincommunication,includingbutnotlimitedtohardwareissues,networkconnectivityissues,and
incorrectcongurationsettings.Somepossibilities:
IstheToolvoxMediaGatewayhardwareconguredandrunning?
HasitbeenaddedtotheManagementClient(calledManagementApplicationinsomeeditions
ofXProtect)?
ArethecongurationdetailsoftheToolvoxcorrect(IPaddress,port,etc.)?
IsthedeviceconnectedtotheToolvoxMediaGateway?
HasitbeenaddedtotheManagementClient(calledManagementApplicationinsomeeditions
ofXProtect)?
Arethecongurationdetailsofthedevicecorrect(IPAddress,port,etc.)?
Checktheloglesforanyrelevantinformation.
“ToolVox offline” alarm shows up even though the ToolVox is running and connected to
the network
IsEventServerrunning?Ifnot,starttheservice.Ifitisalreadyrunning,tryrestartingit.
Checktheloglesforanyrelevantinformation.