Code-blue TOOLVOX X3 Manual de usuario Pagina 102

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 132
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 101
Code Blue
259 Hedcor Street
Holland, MI 49423 USA
800.205.7186
www.codeblue.com GU-154-F
page 102 of 132
ToolVox® X3
Administrator Guide
18 Lightning Protection
Installation procedure for the recommended ToolVox Lightning Protection
ITW SurgeGate CO/25 Module
SurgeGateCO/25modulesareusedtoprotecttheToolVoxAnalogFXO/FXStelephonycard(s)and
Adtran624units.
Installation
1. InstalltheVelcroclampsprovidedwiththeprotector.
2. SecurelymounttheSurgeGatebetweenthe66blockandtheToolVoxMedia
Gateway.
3. ConnectanAmphenolcablefromtheToolVoxtothe“Line”sideoftheSurgeGate.
*Do not connect the SurgeGate directly to the back of the ToolVox. This will
not provide adequate protection and will void the warranty.
4. ConnectanAmphenolcablefromthe66blocktothe“Equipmentsideofthe
SurgeGate.ThiswillbethesidetheCodeBluedevices.
5. SecurebothAmphenolendswiththeVelcromountedontheclampsofthe
SurgeGate.
66 Block/
Code Blue
devices
ToolVox
®
Media Gateway
25pr Amphenol Cable
L
I
N
E
E
Q
U
I
P
M
E
N
T
SurgeGate CO/25
25pr Amphenol Cable
Vista de pagina 101